EasyManuals Logo

Enterasys SecureStack C2 User Manual

Enterasys SecureStack C2
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #157 background imageLoading...
Page #157 background image
Setting Port Link Traps and Link Flap Detection
SecureStack C2 Configuration Guide 5-19
Example
Thisexampleshowshowtoenableflowcontrol:
C2(su)->set flowcontrol enable
Setting Port Link Traps and Link Flap Detection
Purpose
Todisableorreenablelinktraps,displaylinktrapstatus,andtoconfigurethelinkflapping
detectionfunction.Bydefault,allportsareenabledtosendSNMPtrapmessagesindi cating
changestotheirlinkstatus(upordown).
Thelinkflapfunctiondetectswhenalinkisgoingupand
downrapidly(alsocalled“link
flapping”)onaphysicalport,andtakestherequiredactions(disableport,andeventuallysend
notificationtrap)tostopsuchacondition.Ifleftunresolved,the“linkflapping”conditioncanbe
detrimentaltonetworkstabilitybecauseitcantriggerSpanning Treeandroutingtable
recalculation.
Commands
show port trap
UsethiscommandtodisplaywhethertheportisenabledforgeneratinganSNMPtrapmessageif
itslinkstatechanges.
Syntax
show port trap [port-string]
For information about... Refer to page...
show port trap 5-19
set port trap 5-20
show linkflap 5-21
set linkflap globalstate 5-23
set linkflap portstate 5-24
set linkflap interval 5-24
set linkflap action 5-25
clear linkflap action 5-25
set linkflap threshold 5-26
set linkflap downtime 5-26
clear linkflap down 5-27
clear linkflap 5-27

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals