show spantree bpdu-forwarding
SecureStack C2 Configuration Guide 7-9
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheSpanningTreeversion:
C2(su)->clear spantree version
show spantree bpdu-forwarding
Use this command to display the Spanning Tree BPDU forwarding mode.
Syntax
show spantree bpdu-forwarding
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaytheSpanningTreeBPDUforwardingmode:
C2(su)->show spantree bpdu-forwarding
BPDU forwarding is disabled.
set spantree bpdu-forwarding
UsethiscommandtoenableordisableSpanningTreeBPDUforwarding.BydefaultBPDU
forwardingisdisabled.
Syntax
set spantree bpdu-forwarding {disable | enable}
Parameters
disable|enable DisablesorenablesBPDUforwarding;.