set linkflap portstate
5-24 Port Configuration
set linkflap portstate
Usethiscommandtoenableordisablelinkflapmonitoringononeormoreports.
Syntax
set linkflap portstate {disable | enable} [port-string]
Parameters
Defaults
Ifportstringisnotspecified,allportsareenabledordisabled.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoenablethelinktrapmonitoringonallports.
C2(rw)->set linkflap portstate enable
set linkflap interval
Usethiscommandtosetthetimeinterval(inseconds)foraccumulatinglinkdowntransitions.
Syntax
set linkflap interval port-string interval-value
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtosetthelinkflapintervalonportge.1.4to1000seconds.
C2(rw)->set linkflap interval ge.1.4 1000
disable|enable Disablesorenablesthelinkflapdetectionfunction.
portstring (Op tional)Specifiestheportorportsonwhichtodisableorenable
monitoring.
portstring Specifiestheport(s)onwhichtosetthelinkflapinterval.
intervalvalue Specifiesanintervalinseconds.Avalueof0willsettheintervalto
forever.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals