show port inlinepower
SecureStack C2 Configuration Guide 3-29
Syntax
set inlinepower trap {disable | enable} module-number
Parameters
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoenablePoEtrap messagingonmodule1:
C2(su)->set inlinepower trap enable 1
show port inlinepower
UsethiscommandtodisplayallportssupportingPoE.
Syntax
show port inlinepower [port-string]
Parameters
Defaults
Ifnotspecified,informationforallPoEportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayPoEinformationforportge.2.1.Inthiscase,theport’s
administrativestate,PoEpriorityandclasshavenotbeenchangedfromdefaultvalues:
C2(su)->show port inlinepower ge.2.1
Port Type Admin Oper Priority Class Power(W)
---- ---- ----- ---- -------- ----- --------
ge.2.1 wireless auto searching low 0 360
set port inlinepower
UsethiscommandtoconfigurePoEparametersononeormoreports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
disable|enable DisablesorenablesPoEtrapmessaging.
modulenumber Specifiesthemoduleonwhichtodisableorenabletrapmessaging.
portstring (Optional)DisplaysinformationforspecificPoEport(s).