clear vlan name
8-6 802.1Q VLAN Configuration
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoremoveastaticVLAN9fromthedevice’sVLANlist:
C2(su)->clear vlan 9
clear vlan name
UsethiscommandtoremovethenameofaVLANfromtheVLANlist.
Syntax
clear vlan name vlan-list
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoclearthenameforVLAN9:
C2(su)->clear vlan name 9
Assigning Port VLAN IDs (PVIDs) and Ingress Filtering
Purpose
ToassigndefaultVLANIDstountaggedframesononeormoreports,toconfigureVLANingress
filteringand constraints,andtosettheframediscardmode.
vlanlist SpecifiestheVLANIDoftheVLAN(s)toberemoved.
vlanlist SpecifiestheVLANIDoftheVLAN(s)forwhichthenamewillbecleared.