set maclock agefirstarrival
18-54 Security Configuration
Syntax
clear maclock firstarrival port-string
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresetMACfirstarrivalsonge.2.3:
C2(su)->clear maclock firstarrival ge.2.3
set maclock agefirstarrival
UsethiscommandtoenableordisabletheagingoffirstarrivalMACaddresses.Whenenabled,
firstarrivalMACaddressesthatareagedoutoftheforwardingdatabasewillberemovedfrom
theassociatedportMAClock.
Syntax
set maclock agefirstarrival port-string {enable | disable}
Parameters
Defaults
None.
Mode
Switchmode,readwrite.
Example
Thisexampleenablesfirstarrivalagingonportge.1.1.
C2(su)-> set maclock agefirstarrival ge.1.1 enable
portstring Specifiestheportonwhichtoresetthefirstarrivalvalue.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 52.
portstring Specifiestheport(s)onwhichtoenableordisablefirstarrivalaging.For
adetaileddescriptionofpossibleportstringvalues,refertoPortString
SyntaxUsedintheCLIonpage 52.
enable|disable Enableordisablefirstarrivalaging.Bydefault,firstarrivalagingis
disabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals