Using the Command Line Interface
1-8 Introduction
Navigating the Command Line Interface
Getting Help with CLI Syntax
TheSecureStackC2switchallowsyoutodisplayusageandsyntaxinformationforindividual
commandsbytypinghelpor?afterthecommand.
CLI Command Defaults Descriptions
Eachcommanddescriptioninthisguideincludesasectionentitled“Defaults”whichcontains
differentinformationfromthefactorydefaultsettingsontheswitchdescribedinTable 11and
Table 12.ThesectiondefinesCLIbehavioriftheuserentersacommandwithouttypingoptional
parameters(indicatedbysquarebrackets[
]).Forcommandswithoutoptionalparameters,the
defaultssectionlists“None”.Forcommandswithoptionalparameters,thissectiondescribeshow
theCLIrespondsiftheuseroptstoenteronlythekeywordsofthecommandsyntax.Figure 12
providesanexample.
Figure 1-2 Sample CLI Defaults Description
CLI Command Modes
Eachcommanddescriptioninthisguideincludesasectionentitled“Mode” whichstateswhether
thecommandisexecutableinAdmin(SuperUser),ReadWrite,orRead Onlymode.Userswith
ReadOnlyaccesswillonlybepermittedtoviewReadOnly(show)commands.UserswithRead
Writeaccesswillbe
abletomodifyallmodifiableparametersinsetandshowcommands,aswell
asviewReadOnlycommands.AdministratorsorSuperUserswillbeallowedallReadWriteand
ReadOnlyprivileges,andwillbeabletomodifylocaluseraccounts.TheSecureStackC2switch
indicateswhichmodeauser
isloggedinasbydisplayingoneofthefollowingprompts:
•Admin:C2(su)>
•ReadWrite:C2(rw)>
•ReadOnly:C2(ro)>
Performing Keyword Lookups
Enteringaspaceandaquestionmark(?)afterakeywordwilldisplayallcommandsbeginning
withthekeyword.Figure 13showshowtoperformakeywordlookupfortheshowsnmp
command.Inthiscase,fouradditionalkeywordsareusedbytheshowsnmpcommand.Entering
aspaceand
aquestionmark(?)afteranyoftheseparameters(suchasshowsnmpcommunity)
willdisplayadditionalparametersnestedwithinthesyntax.
Figure 1-3 Performing a Keyword Lookup
Syntax
show port status [port-string]
Defaults
Ifportstringisnotspecified,statusinformationforallportswillbedisplayed.
C2(su)->show snmp ?
community SNMP v1/v2c community name configuration
notify SNMP notify configuration
targetaddr SNMP target address configuration
targetparams SNMP target parameters configuration

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals