set igmpsnooping interfacemode
11-4 IGMP Configuration
Example
ThisexampleshowshowtoenableIGMPonthesystem:
C2(su)->set igmpsnooping adminmode enable
set igmpsnooping interfacemode
UsethiscommandtoenableordisableIGMPononeorallports.
Syntax
set igmpsnooping interfacemode port-string {enable | disable}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
InorderforIGMPsnoopingtobeenabledononeorallports,itmustbegloballyenabledonthe
deviceusingthesetigmpsnoopingadminmodecommandasdescribedinsetigmpsnooping
adminmodeonpage 113,andthenenabledonaport(s)usingthiscommand.
Example
ThisexampleshowshowtoenableIGMPonportsge.110:
C2(su)->set igmpsnooping interfacemode ge.1-10 enable
set igmpsnooping groupmembershipinterval
UsethiscommandtoconfiguretheIGMPgroupmembershipintervaltimeforthesystem.
Syntax
set igmpsnooping groupmembershipinterval time
Parameters
portstring SpecifiesoneormoreportsonwhichtoenableordisableIGMP.
enable|disable EnablesordisablesIGMP.
time SpecifiestheIGMPgroupmembershipinterval.Validvaluesare2‐3600
seconds.
Thisvalueworkstogetherwiththesetigmpsnoopingmaxresponsetime
commandtoremoveportsfromanIGMPgroupandmustbegreaterthan
themaxresponsetimevalue.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals