EasyManuals Logo
Home>Enterasys>Switch>SecureStack C2

Enterasys SecureStack C2 User Manual

Enterasys SecureStack C2
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #579 background imageLoading...
Page #579 background image
clear maclock agefirstarrival
SecureStack C2 Configuration Guide 18-55
clear maclock agefirstarrival
Usethiscommandtoresetfirstarrivalagingononeormoreportstoitsdefaultstateofdisabled.
Syntax
clear maclock agefirstarrival port-string
Parameters
Defaults
None.
Mode
Switchmode,readwrite.
Example
Thisexampledisablesfirstarrivalagingonportge.1.1.
C2(su)-> clear maclock agefirstarrival ge.1.1 enable
set maclock move
UsethiscommandtomoveallcurrentfirstarrivalMACstostaticentries.
Syntax
set maclock move port-string
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
IftherearemorefirstarrivalMACsthantheallowedmaximumstaticMACs,thenonlythelatest
firstarrivalMACswillbemovedtostaticentries.Forexample,ifyousetthemaximumnumberof
staticMACsto2withthesetmaclockstaticcommand,andthenexecutedthesetmaclock
move
command,eventhoughtherewerefiveMACsinthefirstarrivaltable,onlythetwomostrecent
MACentrieswouldbemovedtostaticentries.
portstring Specifiestheport(s)onwhichtodisablefirstarrivalaging.Fora
detaileddescriptionofpossibleportstringvalues,refertoPortString
SyntaxUsedintheCLIonpage 52.
portstring SpecifiestheportonwhichMACwillbemovedfromfirstarrivalMACs
tostaticentries.Foradetaileddescriptionofpossibleportstringvalues,
refertoPortStringSyntaxUsedintheCLIonpage 52.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals