clear spantree spanguardtimeout
SecureStack C2 Configuration Guide 7-27
Syntax
set spantree spanguardtimeout timeout
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosettheSpanGuardtimeoutto600seconds:
C2(su)->set spantree spanguardtimeout 600
clear spantree spanguardtimeout
UsethiscommandtoresettheSpanningTreeSpanGuardtimeouttothedefaultvalueof300
seconds.
Syntax
clear spantree spanguardtimeout
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheSpanG uard timeoutto300seconds:
C2(rw)->clear spantree spanguardtimeout
show spantree spanguardlock
UsethiscommandtodisplaytheSpanGuardlockstatusofoneormoreports.
Syntax
show spantree spanguardlock [port-string]
timeout Specifiesatimeoutvalueinseconds.Validvaluesare0to65535.
Avalueof0willkeeptheportlockeduntilmanuallyunlocked.Thedefault
valueis300seconds.