Loading...
clear snmp view
SecureStack C2 Configuration Guide 6-21
Parameters
Defaults
Ifnotspecified,maskwillbesetto255.255.255.255
Ifnotspecified,subtreeusewillbeincluded.
Ifstoragetypeisnotspecified,nonvolatile(permanent)willbeapplied.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetanSNMPMIBviewto“public”withasubtreenameof1.3.6.1
included:
C2(su)->set snmp view viewname public subtree 1.3.6.1 included
clear snmp view
UsethiscommandtodeleteanSNMPv3MIBview.
Syntax
clear snmp view viewname subtree
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtodeleteSNMPMIBview“public”:
C2(su)->clear snmp view public 1.3.6.1
viewnameviewname SpecifiesanameforaMIBview.
subtreesubtree SpecifiesaMIBsubtreename.
maskmask (Optional)Specifiesabitmaskforasubtree.
included|
excluded
(Optional)Specifiessubtreeuse(default)ornosubtreeuse.
volatile|
nonvolatile
(Optional)Specifiestheuseoftemporaryorpermanent(default)storage.
viewname SpecifiestheMIBviewnametobedeleted.
subtree SpecifiesthesubtreenameoftheMIBviewtobedeleted.