set lldp trap-interval
SecureStack C2 Configuration Guide 4-23
Syntax
set lldp hold-multiplier multiplier-val
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexamplesetsthetransm itintervalto20secondsandtheholdmultiplierto5,whichwill
configureatimetoliveof100tobeusedintheTTL fieldintheLLDPDUheader.
C2(rw)->set lldp tx-interval 20
C2(rw)->set lldp hold-multiplier 5
set lldp trap-interval
UsethiscommandtosettheminimumintervalbetweenLLDPnotificationssentbythisdevice.
LLDPnotificationsaresentwhenaremotesystemchangehasbeendetected.
Syntax
set lldp trap-interval frequency
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexamplesetstheminimumintervalbetweenLLDPtrapsto10seconds.
C2(rw)->set lldp trap-interval 10
multiplierval Sp ecifiesthemultipliertoapplytothetransmitintervaltodetermine
thetimetolivevalue.Valuecanrangefrom2to10.Defaultvalueis4.
frequency SpecifiestheminimumtimebetweenLLDPtraptransmissions,in
seconds.Thevaluecanrangefrom5to3600seconds.Thedefault
valueis5seconds.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals