show port ingress filter
SecureStack C2 Configuration Guide 8-9
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoresetportsge.1.3through11toaVLAN IDof1(HostVLAN):
C2(su)->clear port vlan ge.1.3-11
show port ingress filter
Usethiscommandtoshowallportsthatareenabledforportingressfiltering,whichlimits
incomingVLANIDframesaccordingtoaportVLANegresslist.IftheVLANIDspecifiedinthe
receivedframeisnotontheport’sVLANegresslist,thenthatframeisdroppedandnot
forwarded.
Syntax
show port ingress-filter [port-string]
Parameters
Defaults
Ifportstringisnotspecified,ingressfilteringstatusforallportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaytheportingressfilterstatusforports10through15inslot1.
Inthiscase,theportsare disabledforingressfiltering:
C2(su)->show port ingress-filter ge.1.10-15
Port State
-------- ---------
ge.1.10 disabled
ge.1.11 disabled
ge.1.12 disabled
ge.1.13 disabled
ge.1.14 disabled
ge.1.15 disabled
set port ingress filter
UsethiscommandtodiscardallframesreceivedwithaVLANIDthatdon’tmatchtheport’s
VLANegresslist.
Syntax
set port ingress-filter port-string {disable | enable}
portstring (Optional)Specifiestheport(s)forwhichtodisplayingressfilteringstatus.
Foradetaileddescriptionofpossibleportstringvalues,refertoPortString
SyntaxUsedintheCLIonpage 52.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals