set cos reference
SecureStack C2 Configuration Guide 9-27
Syntax
clear cos port-resource irl {all | group-type-index [irl-index [unit] [rate]
[type]]}
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Example
Thisexampleclearsthedatarateto0forIRLresourceindex1forgroup2.0.
C2(su)->clear cos port-resource irl 2.0 1 rate
set cos reference
UsethiscommandtosettheClassofServiceinboundratelimitingreferenceconfiguration.
Syntax
set cos reference irl group-type-index reference rate-limit irl-index
Parameters
irl SpecifiesthatanIRLresourceistobecleared.
all ClearallIRLresourcesforallportgroups.
group‐type‐index Specifiesaninboundratelimitingportgroup/typeindex.Validentriesare
intheformofgroup#.port‐type.
Validvaluesforgroup#canrangefrom0to7.Validvaluesforport
‐type
canrangefrom0to1,althoughonlyporttype0iscurrentlysupported.
Forexample,portgroup3wouldbespecifiedas3.0.
irl‐index (Optional)Inboundratelimiterresourceindexassociatedwiththe
specifiedportgroup.Validvaluesrangefrom0to99.
unit Cleartheunitof
measurefortheinboundratelimiter.
rate Clearthedatarateforthisinboundratelimiter.
type Cleartheactionfortheratelimiter.
irl SpecifiesthatanIRLreferenceisbeingconfigured.
group‐type‐index Specifiesaninboundratelimitingportgroup/typeindex.Validentriesare
intheformofgroup#.port‐type.
Validvaluesforgroup#canrangefrom0to7.Validvaluesforport‐type
canrangefrom0to1,althoughonly
porttype0iscurrentlysupported.
Forexample,portgroup3wouldbespecifiedas3.0.
reference IRLreferencenumberassociatedwiththisentry.