show spantree lpthreshold
SecureStack C2 Configuration Guide 7-45
Defaults
None.Thedefaulteventthresholdis3.
Mode
Switchcommand,readwrite.
Usage
TheLoopProtecteventthresholdisaglobalintegervariablethatprovidesprotectioninthecaseof
intermittentfailures.Thedefaultvalueis3.Iftheeventcounterreachesthethresholdwithina
givenperiod(theeventwindow),thentheport,forthegivenSID,becomeslocked(thatis,held
indefinitelyin
theblockingstate). Ifthethresholdis0,theportsareneverlocked.
Example
ThisexampleshowshowtosettheLoopProtectthresholdvalueto4:
C2(rw)->set spantree lpthreshold 4
show spantree lpthreshold
Usethiscommandtodisplaythecurrentvalueofthe LoopProtecteventthreshold.
Syntax
show spantree lpthreshold
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythecurrentLoopProtectthresholdvalue:
C2(rw)->show spantree lpthreshold
The Loop Protect event threshold value is 4
clear spantree lpthreshold
UsethiscommandtoreturntheLoopProtecteventthresholdtoitsdefaultvalueof3.
Syntax
clear spantree lpthreshold
Parameters
None.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals