EasyManuals Logo

Enterasys SecureStack C2 User Manual

Enterasys SecureStack C2
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #381 background imageLoading...
Page #381 background image
show mac agetime
SecureStack C2 Configuration Guide 12-19
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayMACaddressinformationforge.3.1:
C2(su)->show mac port ge.3.1
MAC Address FID Port Type
----------------- ---- ------------- --------
00-09-6B-0F-13-E6 15 ge.3.1 Learned
MAC Address VLAN Port Type Status Egress Ports
----------------- ---- ------------- ------- ------- ---------------------------
01-01-23-34-45-56 20 any mcast perm ge.3.1
Table 125providesanexplanationofthecommandoutput.
show mac agetime
UsethiscommandtodisplaythetimeoutperiodforaginglearnedMACentries.
Syntax
show mac agetime
Parameters
None.
Defaults
None.
Table 12-5 show mac Output Details
Output What It Displays...
MAC Address MAC addresses mapped to the port(s) shown.
FID Filter database identifier.
Port Port designation.
Type Address type. Valid types are:
Learned
•Self
Management
Other
mcast (multicast)
VLAN The VLAN ID configured for the multicast MAC address.
Status The status of the multicast address.
Egress Ports The ports which have been added to the egress ports list.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals