clear snmp notify
6-32 SNMP Configuration
clear snmp notify
UsethiscommandtoclearanSNMPnotifyconfiguration.
Syntax
clear snmp notify notify
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtocleartheSNMPnotifyconfigurationfor“hello”:
C2(su)->clear snmp notify hello
show snmp notifyfilter
UsethiscommandtodisplaySNMPnotifyfilterinformation,identifyingwhichprofileswillnot
receiveSNMPnotifications.
Syntax
show snmp notifyfilter [profile] [subtree oid-or-mibobject] [volatile |
nonvolatile | read-only]
Parameters
Defaults
Ifnoparametersarespecified,allnotifyfilterinformationwillbedisplayed.
Mode
Switchcommand,readonly.
Usage
SeeAboutSNMPNotifyFiltersonpage 628formoreinformationaboutnotifyfilters.
notify SpecifiesanSNMPnotifynametoclear.
profile (Optional)Displaysaspecificnotifyfilter.
subtreeoidor
mibobject
(Optional)Displaysanotifyfilterwithinaspecificsubtree.
volatile|
nonvolatile|read
only
(Optional)Displaysnotifyfilterentriesofaspecificstoragetype.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals