EasyManuals Logo

Enterasys SecureStack C2 User Manual

Enterasys SecureStack C2
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #215 background imageLoading...
Page #215 background image
clear snmp targetaddr
SecureStack C2 Configuration Guide 6-27
Defaults
Ifnotspecified,udpportwillbesetto162.
Ifnotspecified,maskwillbesetto255.255.255.255
Ifnotspecified,timeoutwillbesetto1500.
Ifnotspecified,numberofretrieswillbesetto3.
Iftaglistisnotspecified,nonewillbeset.
Ifnotspecified,storagetype
willbenonvolatile.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoconfigureatrapnotificationcalledTrapSink.”Thistrapnotification
willbesenttotheworkstation192.168.190.80(whichistargetaddress“tr”).Itwillusesecurityand
authorizationcriteriacontainedinatargetparametersentrycalled“v2cExampleParams”.For
moreinformationonconfiguringabasicSNMPtrap,
refertoCreatingaBasicSNMPTrap
Configurationonpage 636:
C2(su)->set snmp targetaddr tr 192.168.190.80 param v2cExampleParams taglist
TrapSink
clear snmp targetaddr
UsethiscommandtodeleteanSNMPtargetaddressentry.
Syntax
clear snmp targetaddr targetAddr
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoclearSNMPtargetaddressentry“tr”:
C2(su)->clear snmp targetaddr tr
targetAddr Specifiesthetargetaddressentrytodelete.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals