set vlan dynamicegress
8-16 802.1Q VLAN Configuration
VLAN 51 is disabled
VLAN 52 is disabled
VLAN 53 is enabled
VLAN 54 is enabled
VLAN 55 is enabled
set vlan dynamicegress
UsethiscommandtoadministrativelysetthedynamicegressstatusforoneormoreVLANs.
Syntax
set vlan dynamicegress vlan-list {enable | disable}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
IfdynamicegressisenabledforaparticularVLAN,whenaportreceivesaframetaggedwiththat
VLAN’sID,theswitchwilladdthereceivingporttothatVLAN’segresslist.Dynamicegressis
disabledontheSecureStackC2bydefault.
Forexample,assumeyouhave20AppleTalkuserson
yournetworkwhoaremobileusers(thatis,
usedifferentportseveryday),butyouwanttokeeptheAppleTalktrafficisolatedinitsown
VLAN.YoucancreateanAppleTalkVLANwithaVLANIDof55withaclassificationrulethatall
AppleTalktrafficgetstaggedwithVLANID
55.Then,youenabledynamicegressforVLAN55.
Now,whenanAppleTalkuserplugsintoport
ge.3.5andsendsanAppleTalkpacket,theswitch
willtagthepackettoVLAN55andalsoaddport
ge.3.5toVLAN55’segresslist,whichallowsthe
AppleTalkusertoreceiveAppleTalktraffic.
Example
ThisexampleshowshowtoenabledynamicegressonVLAN55:
C2(rw)->set vlan dynamicegress 55 enable
Setting the Host VLAN
Purpose
ToconfigureahostVLANthatonlyselectdevicesareallowedtoaccess.Thissecuresthehostport
formanagementonlytasks.
vlanlist SpecifiestheVLANsbyIDtoenableordisabledynamicegress.
enable|disable Enablesordisablesdynamicegress.