EasyManuals Logo

Enterasys SecureStack C2 User Manual

Enterasys SecureStack C2
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
Reviewing Port Status
SecureStack C2 Configuration Guide 5-3
Portnumbercanbe:
152fortheC2H12448,C2H12448,C2H124 48P
148fortheC2G12448andC2G12448P
124fortheC2G12424andC2G12424P
126fortheC2K122 24
Thehighestvalidportnumberisdependentonthenumberof
portsinthedeviceandtheport
type.
Port Slot/Unit Parameters Used in the CLI
The“unit”parameterisoftenusedinterchangeablywith“module”intheSecureStack CLI to
indicateamoduleslotlocation.
Examples
Thisexampleshowstheportstringsyntaxforspecifyingthe1GigabitEthernetport14inslotunit
3
.
ge.3.14
Thisexampleshowstheportstringsyntaxforspecifyingall1GigabitEthernetportsinslotunit3
inthesystem.
ge.3.*
Thisexampleshowstheportstringsyntaxforspecifyingallports(ofanyinterfacetype)inthe
system.
*.*.*
Reviewing Port Status
Purpose
Todisplayoperatingstatus,duplexmode,speed,porttype,andstatistical informationabout
trafficreceivedandtransmittedthroughoneorallswitchportsonthedevice.
Commands
Thecommandsusedtoreviewportstatusarelistedbelow.
show port
Usethiscommandtodisplaywhetherornotoneormoreportsareenabledforswitching.
Note: You can use a wildcard (*) to indicate all of an item. For example, ge.3.* would represent all
1-Gigabit Ethernet (ge) ports in slot 3.
For information about... Refer to page...
show port 5-3
show port status 5-4
show port counters 5-5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals