Reviewing Port Status
SecureStack C2 Configuration Guide 5-3
Portnumbercanbe:
152fortheC2H12448,C2H12448,C2H124 48P
148fortheC2G12448andC2G12448P
124fortheC2G12424andC2G12424P
126fortheC2K122 24
Thehighestvalidportnumberisdependentonthenumberof
portsinthedeviceandtheport
type.
Port Slot/Unit Parameters Used in the CLI
The“unit”parameterisoftenusedinterchangeablywith“module”intheSecureStack CLI to
indicateamoduleslotlocation.
Examples
Thisexampleshowstheportstringsyntaxforspecifyingthe1GigabitEthernetport14inslotunit
3
.
ge.3.14
Thisexampleshowstheportstringsyntaxforspecifyingall1GigabitEthernetportsinslotunit3
inthesystem.
ge.3.*
Thisexampleshowstheportstringsyntaxforspecifyingallports(ofanyinterfacetype)inthe
system.
*.*.*
Reviewing Port Status
Purpose
Todisplayoperatingstatus,duplexmode,speed,porttype,andstatistical informationabout
trafficreceivedandtransmittedthroughoneorallswitchportsonthedevice.
Commands
Thecommandsusedtoreviewportstatusarelistedbelow.
show port
Usethiscommandtodisplaywhetherornotoneormoreportsareenabledforswitching.
Note: You can use a wildcard (*) to indicate all of an item. For example, ge.3.* would represent all
1-Gigabit Ethernet (ge) ports in slot 3.
For information about... Refer to page...
show port 5-3
show port status 5-4
show port counters 5-5

Table of Contents