Syntax
set rmon alarm properties index [interval interval] [object object] [type
{absolute | delta}] [startup {rising | falling | either}] [rthresh rthresh]
[fthresh fthresh] [revent revent] [fevent fevent] [owner owner]
Parameters
index Specifiesanindexnumberforthisentry.Maximumnumberorentriesis
50.Maximumvalueis65535.
intervalinterval (Optional)Specifiesaninterval(inseconds)forRMONtoconductsample
monitoring.
objectobject (Optional)SpecifiesaMIBobjecttobemonitored.
Note: This parameter is not mandatory for executing the command, but
must be specified in order to enable the alarm entry configuration.
typeabsolute|
delta
(Optional)Specifiesthemonitoringmethodas:samplingtheabsolute
valueoftheobject,orthedifference(delta)betweenobjectsamples.
startuprising|
falling|either
(Optional)Specifiesthetypeofalarmgeneratedwhenthiseventisfirst
enabledas:
• Rising‐SendsalarmwhenanRM ONeventreachesa
maximum
thresholdconditionisreached,forexample,morethan30collisions
persecond.
•Falling‐SendsalarmwhenRMONeventfallsbelowaminimum
thresholdcondition,forexamplewhenthenetworkisbehaving
normallyagain.
•Either‐Sendsalarmwheneitherarisingorfallingthresholdis
reached.
rthreshrthresh (Optional)Specifiesaminimum
thresholdforcausingarisingalarm.
fthreshfthresh Specifiesamaximumthresholdforcausingafallingalarm.
reventrevent SpecifiestheindexnumberoftheRMONeventtobetriggeredwhenthe
risingthresholdiscrossed.
feventfevent SpecifiestheindexnumberoftheRMONeventtobetriggeredwhenthe
fallingthreshold
iscrossed.
ownerowner (Optional)Specif iesthenameoftheentitythatconfiguredthisalarm
entry.