EasyManuals Logo

Enterasys SecureStack C2 User Manual

Enterasys SecureStack C2
607 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #405 background imageLoading...
Page #405 background image
set rmon alarm properties
SecureStack C2 Configuration Guide 13-9
set rmon alarm properties
UsethiscommandtoconfigureanRMONalarmentry,ortocreateanewalarmentrywithan
unusedalarmindexnumber.
Syntax
set rmon alarm properties index [interval interval] [object object] [type
{absolute | delta}] [startup {rising | falling | either}] [rthresh rthresh]
[fthresh fthresh] [revent revent] [fevent fevent] [owner owner]
Parameters
index Specifiesanindexnumberforthisentry.Maximumnumberorentriesis
50.Maximumvalueis65535.
intervalinterval (Optional)Specifiesaninterval(inseconds)forRMONtoconductsample
monitoring.
objectobject (Optional)SpecifiesaMIBobjecttobemonitored.
Note: This parameter is not mandatory for executing the command, but
must be specified in order to enable the alarm entry configuration.
typeabsolute|
delta
(Optional)Specifiesthemonitoringmethodas:samplingtheabsolute
valueoftheobject,orthedifference(delta)betweenobjectsamples.
startuprising|
falling|either
(Optional)Specifiesthetypeofalarmgeneratedwhenthiseventisfirst
enabledas:
Rising‐SendsalarmwhenanRM ONeventreachesa
maximum
thresholdconditionisreached,forexample,morethan30collisions
persecond.
•Falling‐SendsalarmwhenRMONeventfallsbelowaminimum
thresholdcondition,forexamplewhenthenetworkisbehaving
normallyagain.
•Either‐Sendsalarmwheneitherarisingorfallingthresholdis
reached.
rthreshrthresh (Optional)Specifiesaminimum
thresholdforcausingarisingalarm.
fthreshfthresh Specifiesamaximumthresholdforcausingafallingalarm.
reventrevent SpecifiestheindexnumberoftheRMONeventtobetriggeredwhenthe
risingthresholdiscrossed.
feventfevent SpecifiestheindexnumberoftheRMONeventtobetriggeredwhenthe
fallingthreshold
iscrossed.
ownerowner (Optional)Specif iesthenameoftheentitythatconfiguredthisalarm
entry.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals