18-58 Security Configuration
show pwa
Usethiscommandtodisplayportwebauthenticationinformationforoneormoreports.
Syntax
show pwa [port-string]
Parameters
Defaults
Ifportstringisnotspecified,PWAinformationwillbedisplayedforallports.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayPWAinformationforge.2.1:
C2(su)->show pwa ge.2.1
PWA Status - enabled
PWA IP Address - 192.168.62.99
PWA Protocol - PAP
PWA Enhanced Mode - N/A
PWA Logo - enabled
PWA Guest Networking Status - disabled
PWA Guest Name - guest
PWA Redirect Time - N/A
Port Mode AuthStatus QuietPeriod MaxReq
-------- ---------------- -------------- ----------- ---------
ge.2.1 disabled disconnected 60 16
Table 188providesanexplanationofthecommandoutput.
set pwa quietperiod 18-65
set pwa maxrequest 18-66
set pwa portcontrol 18-66
show pwa session 18-67
set pwa enhancedmode 18-68
For information about... Refer to page...
portstring (Optional)DisplaysPWAinformationforspecificport(s).
Table 18-8 show pwa Output Details
Output What It Displays...
PWA Status Whether or not port web authentication is enabled or disabled. Default state of
disabled can be changed using the set pwa command as described in “set pwa” on
page 18-59.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals