show maclock
SecureStack C2 Configuration Guide 18-47
show maclock
UsethiscommandtodisplaythestatusofMAClockingononeormoreports.
Syntax
show maclock [port-string]
Parameters
Defaults
Ifportstringisnotspecified,MAClockingstatuswillbedisplayedforallports.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayMAClockinginformationforge.1.1.
C2(su)->show maclock ge.1.1
MAC locking is globally enabled
Port Port Trap Aging Max Static Max FirstArrival Last Violating
Number Status Status Status Allocated Allocated MAC Address
------- ------- -------- ------- ---------- --------------- ---------------
ge.1.1 enabled disabled enabled 20 1 00:a0:c9:39:5c:b4
Table 186providesanexplanationofthecommandoutput.
clear maclock 18-51
set maclock static 18-52
clear maclock static 18-52
set maclock firstarrival 18-53
clear maclock firstarrival 18-53
set maclock agefirstarrival 18-54
clear maclock agefirstarrival 18-55
set maclock move 18-55
set maclock trap 18-56
For information about... Refer to page...
portstring (Optional)DisplaysMAClockingstatusforspecifiedport(s).Fora
detaileddescriptionofpossibleportstringvalues,refertoPortString
SyntaxUsedintheCLIonpage 52.
Table 18-6 show maclock Output Details
Output What It Displays...
Port Number Port designation. For a detailed description of possible port-string values, refer to
Port String Syntax Used in the CLI” on page 5-2.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals