show lldp port local-info
SecureStack C2 Configuration Guide 4-19
Example
Thisexampleshowshowtodisplaythelocalsysteminformationstoredforportge.4.1.Table 4‐4
describestheoutputfieldsofthiscommand.
C2(rw)->show lldp port local-info ge.4.1
Local Port : ge.4.1 Local Port Id: ge.4.1
--------------------
Port Desc : ... 1000BASE-TX RJ45 Gigabit Ethernet Frontpanel Port
Mgmt Addr : 10.21.64.100
Chassis ID : 00-E0-63-93-74-A5
Sys Name : LLDP PoE test Chassis
Sys Desc : Enterasys Networks, Inc.
Sys Cap Supported/Enabled : bridge,router/bridge
Auto-Neg Supported/Enabled : yes/yes
Auto-Neg Advertised : 10BASE-T, 10BASE-TFD,
100BASE-TX, 100BASE-TXFD,
1000BASE-TFD,
Bpause
Operational Speed/Duplex/Type : 100 full tx
Max Frame Size (bytes) : 1522
Vlan Id : 1
LAG Supported/Enabled/Id : no/no/0
Protocol Id : Spanning Tree v-3 (IEEE802.1s)
LACP v-1
GVRP
PoE Device : PSE device
PoE Power Source : primary
PoE MDI Supported/Enabled : yes/yes
PoE Pair Controllable/Used : false/spare
PoE Power Class : 2
PoE Power Limit (mW) : 15400
PoE Power Priority : high
Table 4‐4describestheinformationdisplayedbytheshowlldpportlocal‐infocommand.
Table 4-4 show lldp port local-info Output Details
Output Field What it Displays...
Local Port Identifies the port for which local system information is displayed.
Local Port Id Mandatory basic LLDP TLV that identifies the port transmitting the
LLDPDU. Value is ifName object defined in RFC 2863.
Port Desc Optional basic LLDP TLV. Value is ifDescr object defined in RFC 2863.
Mgmt Addr Optional basic LLDP TLV. IPv4 address of host interface.
Chassis ID Mandatory basic LLDP TLV that identifies the chassis transmitting the
LLDPDU. Value is MAC address of chassis.
Sys Name Optional basic LLDP TLV. Value is the administratively assigned name for
the system.
Sys Desc Optional basic LLDP TLV. Value is sysDescr object defined in RFC 3418.
Sys Cap Supported/Enabled Optional basic LLDP TLV. System capabilities, value can be bridge and/or
router.