set port lacp
5-44 Port Configuration
Defaults
Atleastoneparametermustbeenteredperportstring.
Ifenableordisablearenotspecified,port(s)willbeenabledwiththeLACPparametersentered.
aadminstate
lacpactive|
lacptimeout|
lacpagg|lacpsync
|lacpcollect|
lacpdist|lacpdef|
lacpexpire
Setstheport’sactorLACPadministrativestatetoallowfor:
lacpactive‐TransmittingLACPPDUs.
lacptimeoutTransmittingLACPPDUsevery1sec.vs30sec.(default).
lacpagg‐Aggregationonthisport.
lacpsync‐Transitiontosynchronizationstate.
lacpcollect‐Transitiontocollectionstate.
lacpdist‐Transitiontodistributionstate.
lacpdef‐Transitiontodefaultedstate.
lacpexpire‐Transitiontoexpiredstate.
aportpriaportpri Setstheport’sactor
portpriority.Validvaluesare0‐65535,withlower
valuesdesignatinghigherpriority.
asyspriasyspri Setstheport’sactorsystempriority.TheLACPimplementationonthe
SecureStackC2deviceusesthisvaluetodetermineaggregation
precedencewhentherearetwodevicescompetingforthesame
aggregator.Validvaluesare0‐65535
,withhigherprecedencegivento
lowervalues.
Note: Only one LACP system priority can be set on a SecureStack
C2 device, using either this command, or the set lacp asyspri
command (“set lacp asyspri” on page 5-37).
enable (Optional)EnablesLACPDUprocessingonthisport.
disable (Optional)DisablesLACPDUprocessingonthisport.
padminkey
padminkey
Setsadefaultvaluetouseastheport’spartneradminkey.Onlyports
withmatchingadminkeysareallowedtoaggregate.Validvaluesare1‐
65535.
padminport
padminport
Setsadefaultvaluetouse
astheport’s partneradminvalue.Validvalues
are1‐65535.
padminportpri
padminportpri
Setsadefaultvaluetouseastheport’spartnerportpriority.Validvalues
are0‐65535,withlowervaluesgivenhigherpriority.
padminstate
lacpactive|
lacptimeout|
lacpagg|lacpsync
|lacpcollect|
lacpdist|lacpdef|
lacpexpire
Setsaport’spartnerLACPadministrativestate.Seeaadminstateforvalid
options.
padminsysid
padminsysid
Setsadefaultvaluetouseastheport’spartnersystemID.ThisisaMAC
address.
padminsyspri
padminsyspri
Setsadefaultvaluetouseastheport’spartnerpriority.Validvaluesare0
‐65535,withlower
valuesgivenhigherpriority.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals