show policy rule
9-6 Policy Classification Configuration
Syntax
show policy rule [all | admin-profile | profile-index] [ether | icmptype | ipproto
| ipdestsocket | ipsourcesocket | iptos | macdest | macsource | tcpdestport |
tcpsourceport | udpdestport | udpsourceport] [data] [mask mask] [port-string port-
string] [rule-status {active | not-in-service | not-ready}] [storage-type {non-
volatile | volatile}] [vlan vlan] | [drop | forward] [dynamic-pid dynamic-pid]
[cos cos] [admin-pid admin-pid] [-verbose] [usage-list] [display-if-used]
Parameters
all|admin
profile|profile
index
Displayspolicyclassificationrulesforallprofiles,profileID0(admin
profile),orforaspecificprofileindexnumber.Validvaluesare1‐1023.
ether DisplaysEthernettypeIIrules.
icmptype DisplaysICMPtyperules.
ipproto DisplaysIPprotocolfieldinIPpacketrules.
ipdestsocket Displays
IPdestinationaddressrules.
ipsourcesocket DisplaysIPsourceaddressrules.
iptos DisplaysTypeofServicerules.
macdest DisplaysMACdestinationaddressrules.
macsource DisplaysMACsourceaddressrules.
tcpdestport DisplaysTCPdestinationportrules.
tcpsourceport DisplaysTCPsourceportrules.
udpdestport DisplaysUDPdestinationportrules.
udpsourceport DisplaysUDPsourceportrules.
data Displaysrulesforapredefined
classifier.Thisvalueisdependentonthe
classificationtypeentered.RefertoTable 93forvalidvaluesfor each
classificationtype.
maskmask (Optional)Displaysrulesforaspecificdatamask.RefertoTable 93 for
validvaluesforeachclassificationtypeanddatavalue.
portstringport
string
(Optional)Displaysrules
relatedtoaspecificingressport.
rulestatusactive
|notinservice|
notready
(Optional)Displaysrulesrelatedtoaspecificrulesstatus.
storagetypenon
volatile|volatile
(Optional)Displaysrulesconfiguredforeithernonvolatileorvolatile
storage.
vlanvlan (Optional)DisplaysrulesforaspecificVLANID.
drop|
forward Displaysrulesbasedonwhethermatchingpacketswillbedroppedor
forwarded.
dynamicpid
dynamicpid
DisplaysrulesassociatedwithaspecificdynamicpolicyID.
coscos (Optional)DisplaysrulesforaClassofServicevalue.(Notsupportedon
B3,C3devices.)
adminpid
adminpid
Displaysrulesassociatedwithaspecificadministrative
policyID[1..1023].

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 and is the answer not in the manual?

Enterasys SecureStack C2 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2
CategorySwitch
LanguageEnglish

Related product manuals