AT-9000 Switch Command Line User’s Guide
1027
NO SNMP-SERVER VIEW
Syntax
no snmp-server view
viewname
oid
Parameters
viewname
Specifies the name of the view to be deleted. The name is case
sensitive.
oid
Specifies the OID of the view.
Mode
Global Configuration mode
Description
Use this command to delete SNMP views. You can delete just one view at
a time with this command.
Confirmation Command
“SHOW SNMP-SERVER VIEW” on page 1033
Example
This example deletes the view AlliedTelesis with the OID 1.3.6.1.4.1.207:
awplus> enable
awplus# configure terminal
awplus(config)# no snmp-server view AlliedTelesis
1.3.6.1.4.1.207