Page #831 background imageLoading...
Page #831 background image
AT-9000 Switch Command Line User’s Guide
831
GVRP TIMER LEAVE
Syntax
gvrp timer leave
value
Parameters
value
Specifies the Leave Timer in centiseconds, which are one
hundredths of a second. The range is 30 to 180 centiseconds. The
default is 60 centiseconds.
Mode
Global Configuration mode
Description
Use this command to set the GARP Leave Timer.
Note
The setting for this timer must be the same on all GVRP-active
network devices.
Example
This command sets the Leave Timer to 0.8 seconds:
awplus> enable
awplus# configure terminal
awplus(config)# gvrp timer leave 80