AT-9000 Switch Command Line User’s Guide
1141
LLDP REINIT
Syntax
lldp reinit
delay
Parameters
delay
Specifies the re-initialization delay value. The range is 1 to 10
seconds.
Mode
Global Configuration mode
Description
Use this command to set the re-initialization delay. This is the number of
seconds that must elapse after LLDP is disabled on a port before it can be
re-initialized.
Confirmation Command
“SHOW LLDP” on page 1165.
Example
This example set the re-initialization delay to 8 seconds:
awplus> enable
awplus# configure terminal
awplus(config)# lldp reinit 8

Table of Contents