Setting the GVRP Timers
The switch has a Join Timer, a Leave Timer, and a Leave All Timer. You
should not change the timers unless you understand their functions. (Refer
to the IEEE 802.1p standard for the definitions.) The timers have to be set
the same on all GARP-active network devices, and the Join Timer and
Leave Timer have to be set according to the following equation:
Join Timer <= (2 x (Leave Timer))
The commands for setting the timers are in the Global Configuration
mode. They are:
gvrp timer join
value
gvrp timer leave
value
gvrp timer leaveall
value
The timers are set in one hundredths of a second. This example sets the
Join Timer to 0.2 seconds, the Leave Timer to 0.8 seconds and the Leave
All timer to 10 seconds:
awplus> enable
awplus# configure terminal
awplus(config)# gvrp timer join 20
awplus(config)# gvrp timer leave 80
awplus(config)# gvrp timer leaveall 1000
For reference information, refer to “GVRP TIMER JOIN” on page 830,
“GVRP TIMER LEAVE” on page 831 and “GVRP TIMER LEAVEALL” on
page 832.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AT-9000 Series and is the answer not in the manual?

Allied Telesis AT-9000 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelAT-9000 Series
CategorySwitch
LanguageEnglish

Related product manuals