AT-9000 Switch Command Line User’s Guide
835
NO GVRP TIMER LEAVE
Syntax
no gvrp timer leave value
Parameters
None
Mode
Global Configuration mode
Description
Use this command to disable the GARP Leave Timer and return the GVRP
Leave Timer to its default value. This timer must only be disabled in
relation to the GVRP Join Timer according to the following equation:
Join Timer <= (2 x (GVRP Leave Timer))
Note
The setting for this timer must be the same on all GVRP-active
network devices.
Example
This command sets the Leave Timer to 0.6 seconds:
awplus> enable
awplus# configure terminal
awplus(config)# no gvrp timer leave