Accumulated Call Meter Maximum - +CAMM
+CAMM - Accumulated Call Meter Maximum
SELINT 2
AT+CAMM=
[<acmmax>
[,<pwd>]]
Set command sets the Advice of Charge related Accumulated Call Meter Maximum
Value stored in SIM (ACMmax). This value represents the maximum number of
home units allowed to be consumed by the subscriber. When ACM reaches
<acmmax> value further calls are prohibited.
Parameter:
<acmmax> - ACMmax value, integer type: it is the maximum number of home
units allowed to be consumed by the subscriber.
<pwd> - PIN2; if PIN2 has been already input once after startup, it is
required no more
Note: <acmmax> = 0 value disables the feature.
AT+CAMM?
Read command reports the ACMmax value stored in SIM in the format:
+CAMM : <acmm>
where:
<acmm> - ACMmax value in home units, string type: three bytes of the ACMmax
value in hexadecimal format (e.g. “00001E” indicates decimal value 30)
AT+CAMM=?
Test command returns the OK result code
Reference
3GPP TS 27.007
Price per Unit and Currency Table - +CPUC
+CPUC - Price Per Unit And Currency Table
SELINT 2
AT+CPUC=
<currency>,
<ppu>[,<pwd>]
Set command sets the values of Advice of Charge related Price per Unit and
Currency Table stored in SIM (PUCT). The PUCT information can be used to
convert the home units (as used in commands +CAOC, +CACM and +CAMM)
into currency units.
Parameters:
<currency> - string type; three-character currency code (e.g. “LIT”, “L. “,
“USD”, “DEM” etc..); used character set should be the one selected with
command +CSCS.
<ppu> - price per unit, string type (dot is used as decimal separator) e.g.
“1989.27”
<pwd> - SIM PIN2; if PIN2 has been already input once after startup, it is required
no more
AT+CPUC?
Read command reports the current values of <currency> and <ppu> parameters
in the format:
+CPUC : <currency>,<ppu>

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910 and is the answer not in the manual?

Telit Wireless Solutions LE910 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910
CategoryControl Unit
LanguageEnglish

Related product manuals