Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 53 of 509
Mod. 0808 2011-07 Rev.2
S1 is incremented each time the device detects the ring signal of an incoming call.
S1 is cleared as soon as no ring occur.
Note: the form ATS1 has no effect.
Read command returns the value of this parameter.
Escape Character - S2
Set command sets the ASCII character to be used as escape character.
Parameter:
<char> - escape character decimal ASCII
0..255 - factory default value is 43 (+).
Note: the escape sequence consists of three escape characters preceded and
followed by n ms of idle (see S12 to set n).
Read command returns the current value of S2 parameter.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
Command Line Termination Character - S3
S3 - Command Line Termination Character
Set command sets the value of the character either recognized by the device as
command line terminator and generated by the device as part of the header, trailer,
and terminator for result codes and information text, along with S4 parameter.
Parameter:
<char> - command line termination character (decimal ASCII)
0..127 - factory default value is 13 (ASCII <CR>)
Note: the “previous” value of S3 is used to determine the command line termination
character for entering the command line containing the S3 setting command.
However the result code issued shall use the “new” value of S3 (as set during the
processing of the command line)
Read command returns the current value of S3 parameter.