EasyManuals Logo

Telit Wireless Solutions LE910 User Manual

Telit Wireless Solutions LE910
509 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #377 background imageLoading...
Page #377 background image
Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 377 of 509
Mod. 0808 2011-07 Rev.2
FTP Get - #FTPGET
#FTPGET - FTP Get
SELINT 2
AT#FTPGET=
[<filename>]
Execution command, issued during an FTP connection, opens a data connection and
starts getting a file from the FTP server.
If the data connection succeeds a CONNECT indication is sent.
The file is received on the serial port.
Parameter:
<filename> - file name, string type.
Note: The command causes an ERROR result code to be returned in case no FTP
connection has been opened yet.
Note: Command closure should always be handled by application. In order to avoid
download stall situations a timeout should be implemented by the application.
AT#FTPGET=?
Test command returns the OK result code.
FTP GET in command mode - #FTPGETPKT
#FTPGETPKT - FTP Get in command mode
SELINT 2
AT#FTPGETPKT=
<filename>
[,<viewMode>]
Execution command, issued during an FTP connection, opens a data connection
and starts getting a file from the FTP server while remaining in command mode.
The data port is opened and we remain in command mode and we see the result
code OK.
Retrieval from FTP server of “remotefile” is started, but data are only buffered in
the module.
It’s possible to read data afterwards issuing #FTPRECV command
Parameters:
<filename> - file name, string type. (maximum length: 200 characters).
<viewMode> - permit to choose view mode
(text format or Hexadecimal)
0 – text format (default)
1 – hexadecimal format
Note: The command causes an ERROR
result code to be returned in case no FTP
connection has been opened yet.
Note: Command closure should always be handled by application. In order
to avoid download stall situations a timeout should be implemented by the
application.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910 and is the answer not in the manual?

Telit Wireless Solutions LE910 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910
CategoryControl Unit
LanguageEnglish

Related product manuals