S3 - Command Line Termination Character
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
Response Formatting Character - S4
S4 - Response Formatting Character
Set command sets the value of the character generated by the device as part of the
header, trailer, and terminator for result codes and information text, along with the
S3 parameter.
Parameter:
<char> - response formatting character (decimal ASCII)
0..127 - factory default value is 10 (ASCII LF)
Note: if the value of S4 is changed in a command line the result code issued in
response of that command line will use the new value of S4.
Read command returns the current value of S4 parameter.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s