#SWMGETDP – Download update package from OMA-DM software management server.
#SWMCHKUPD: 1,1024,”Description of update package”,”Release Note
URL”
AT#SWMGETDP=1
OK
#SWMDLPRGRSS: 0,1024
#SWMDLPRGRSS: 1024,1024
#SWMRING: 2,”Description of update package”,”Release Note URL”
Install software update package - #SWMDEPLOYDP
#SWMDEPLOYDP – Install software update package
atus>
Execution command confirms SWM client to install update package after a
URC
#SWMRING: 2[,<description>[,<releaseNoteURL>]]
Parameters:
<status> - User action for confirmation
0 – Reject
1 – Accept
Note: if the update requires a device reboot, the device will be rebooted
silently.
Note: when a FUMO update is done, a URC is received
#SWMRING: <notificationId>[<description>[,<releaseNoteURL>]]
where:
<notificationId>
4 – Firmware update successfully deployed
5 – Firmware update failed
Note: the command raises an error if issued before AT#SWMENA=1.
Test command reports the supported range of values for the <status>
parameter.