Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 316 of 509
Mod. 0808 2011-07 Rev.2
Event Monitoring - #EVMONI
#EVMONI Set the single Event Monitoring
SELINT 2
AT#EVMONI=
<label>,
<mode>,
[,<paramType >
,<param>]
Set command enables/disables the single event monitoring, configures the related
parameter and associates the AT command
<label>: string parameter (that has to be enclosed between double quotes)
indicating the event under monitoring. It can assume the following values:
VBATT - battery voltage monitoring
DTR - DTR monitoring
ROAM - roaming monitoring
CONTDEACT - context deactivation monitoring
RING - call ringing monitoring
STARTUP – module start-up monitoring
REGISTERED – network registration monitoring
GPIO1 – monitoring on a selected GPIO in the GPIO range
GPIO2 – monitoring on a selected GPIO in the GPIO range
GPIO3 – monitoring on a selected GPIO in the GPIO range
GPIO4 – monitoring on a selected GPIO in the GPIO range
GPIO5 – monitoring on a selected GPIO in the GPIO range
ADCH1 – ADC High Voltage monitoring
ADCL1 – ADC Low Voltage monitoring
DTMF1 –monitoring on user defined DTMF string
DTMF2 –monitoring on user defined DTMF string
DTMF3 –monitoring on user defined DTMF string
DTMF4 –monitoring on user defined DTMF string
SMSIN – monitoring on incoming SMS
CONSUME1 – used to define an action to be used in consume functionality
(see parameter <action_id> in #CONSUMECFG command)
CONSUME2 – used to define an action to be used in consume functionality
(see parameter <action_id> in #CONSUMECFG command)
CONSUME3 – used to define an action to be used in consume functionality
(see parameter <action_id> in #CONSUMECFG command)
CONSUME4 – used to define an action to be used in consume functionality
(see parameter <action_id> in #CONSUMECFG command)
CONSUME5 – used to define an action to be used in consume functionality
(see parameter <action_id> in #CONSUMECFG command)
<mode>:
0 – disable the single event monitoring (default)
1 – enable the single event monitoring
< paramType >: numeric parameter indicating the type of parameter contained in
<param>. The 0 value indicates that <param> contains the AT command string to

Table of Contents