Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 317 of 509
Mod. 0808 2011-07 Rev.2
#EVMONI – Set the single Event Monitoring
execute when the related event has occurred. Other values depend from the type of
event.
<param>: it can be a numeric or string value depending on the value of
<paramType> and on the type of event.
If <paramType> is 0, then <param> is a string containing the AT command:
• It has to be enclosed between double quotes
• It has to start with the 2 chars AT (or at)
•
If the string contains the character ”, then it has to be replaced with the 3
characters \22
• the max string length is 96 characters
• if it is an empty string, then the AT command is erased
• If <label> is VBATT, <paramType> can assume values in the range 0 - 2.
o if <paramType> = 1, <param>
indicates the battery voltage
threshold in the range 0 –
500, where one unit corresponds to 10 mV
(therefore 500 corresponds to 5 V). (Default: 0)
o if <paramType> = 2, <param> indicates the time interval in
seconds after that the voltage battery under the value specified with
<paramType> = 1 causes the event. The range is 0 – 255. (Default:
0)
• If <label> is DTR, <paramType> can assume values in the range 0 - 2.
o if <paramType> = 1, <param>
indicates the status high or low
under monitoring. The values are 0 (low) and 1 (high). (Default: 0)
o if <paramType> = 2, <param>
indicates the time interval in
seconds after that the DTR in the status specified with
<paramType> = 1 causes the event. The range is 0 – 255. (Default:
0)
• If <label> is ROAM, <paramType>
can assume only the value 0. The event
under monitoring is the roaming state.
• If <label> is CONTDEACT, <paramType>
can assume only the value 0.
The event under monitoring is the context deactivation.
• If <label> is RING, <paramType> can assume values in the range 0 - 1.
o if <paramType> = 1, <param>
indicates the numbers of call rings
after that the event occurs. The range is 1-50. (Default: 1)
• If <label> is STARTUP, <paramType>
can assume only the value 0. The
event under monitoring is the module start-up.
• If <label> is REGISTERED, <paramType>
can assume only the value 0.
The event under monitoring is the network registr
ation (to home network or
in roaming) after the start-up and the SMS ordening.
• If <label> is GPIOX, <paramType> can assume values in the range 0 - 3.
o if <paramType> = 1, <param>
indicates the GPIO pin number;
supported range is from 1 to a value that depends on the hardware.