+CEREG – EPS network registration status
+CEREG: (list of supported <n>s)
Set Mode of operation for EPS - +CEMODE
+CEMODE – Set mode of operation for EPS.
Set command configures the mode of operation for EPS
Parameter:
a numeric parameter which indicates the mode of operation
0 : PS mode 2 of operation
1 : CS/PS mode 1 of operation
2 : CS/PS mode 2 of operation
3 : PS mode 1 of operation
the definition for UE modes of operation can be found in
3GPP TS 24.301 [83]
Other values are reserved and will result in an ERROR response to the
set command.
Read command returns the currently configured values, in the format:
+CEMODE
:
The read command will return right values after set command.
But effectively the mode of operation changes after power cycle.
Test command returns the supported range of values of parameters <
mode>
OK
AT+CEMODE?
+CEMODE: 1
Extended Signal Quality - +CESQ