#TEMPMON: <urcmode>,<action>[,<hyst_time>[,<GPIO>]]
AT#TEMPMON=?
Test command reports the supported range of values for parameters <mod>,
<urcmode>, <action>, <hyst_time> and <GPIO>
The following table is describing the temperature levels.
Extreme Temperature Lower Bound
-30°C
Operating Temperature Lower Bound -10°C
Operating Temperature
Operating Temperature Upper Bound 55°C
Extreme Temperature Upper Bound 80°C
Temperature monitor configuration - #TEMPCFG
#TEMPCFG – Temperature monitor configuration
<TempExLowBound>
[,<TempOpLowBound>
[,<TempOpUpBound>
[,<TempExUpBound>]]]
This parameter command manages the temperature range used by the
TEMPMON command
Parameters:
<TempExLowBound> - the extreme temperature lower limit
<TempOpLowBound> - the operating temperature lower limit
<TempOpUpBound> - the operating temperature upper limit
<TempExUpBound> - the extreme temperature upper limit
Note 1: The extreme temperature lower limit must not be lower than lower
limit (see TEMPMON for temperature limits);
Note 2: the operating temperature lower limit must be bigger than the
extreme temperature lower
limit, and not lower than its minimum admitted
value (see TEMPMON for temperature limits);
Note 3: the operating temperature upper limit must be bigger than the
operating temperature lower limit, and not lower than its minimum
admitted value (see TEMPMON for temperature limits);