Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 336 of 509
Mod. 0808 2011-07 Rev.2
Socket configuration Extended 3 - #SCFGEXT3
#SCFGEXT3 - Socket Configuration Extended 3
AT#SCFGEXT3=
<connId
>,<immRsp>[,
<closureTypeCmdM
odeEnabling>
[,<fastsring>[,<unus
ed_C>[,<unused_D>
]]]]
Set command sets the socket configuration extended parameters for features
not included in #SCFGEXT command nor in #SCFGEXT2 command
Parameters:
socket connection identifier
Enables AT#SD command mode immediate response
0 – factory default, means that AT#SD in command mode (see
) returns
after the socket is connected
1 – means that AT#SD in command mode returns immediately. Then the state
of the connection can be read by the AT command
AT#SS
<closureTypeCmdModeEnabling> -
Setting this parameter, successive #SD or #SL with
parameter 255 setting takes effect in command mode.
It has been introduced due to retrocompatibility reason regarding
behaviour in command mode.
0 – factory default, #SD or #SL
255 in command mode has no
effect
1 – #SD or SL
255 in command mode takes effect
Enables the fast SRING (active only when
parameter
=2) in TCP and UDP sockets
0 – factory default, means that SRING unsolicited is received periodically if
data are available every 200ms.
1 – means that if data are available SRING unsolicited is received
asynchronous as fast as possible.
Note: parameters are saved in NVM
Read command returns the current socket extended configuration parameters
values for all the six sockets, in the format:
#SCFGEXT3:<connId1>,<immRsp1>, <closureTypeCmdModeEnabling>,<
fastsring >,0,0<CR><LF>