Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 260 of 509
Mod. 0808 2011-07 Rev.2
<deviceId>: address of the I2C device, with the LSB, used for read\write
command. It doesn’t matter if the LSB is set to 0 or to 1. 10 bit addressing
supported.
Value has to be written in hexadecimal form (without 0x before).
<registerId>: Register to read data from, range 0..255.
Value has to be written in hexadecimal form (without 0x before).
<len>: number of data to receive. Valid range is 1-254.
Data Read from I2C will be dumped in Hex:
NOTE: If data requested are more than data available in the device, dummy data
( normally 0x00 or 0xff ) will be dumped.
NOTE: At the end of the execution GPIO will be restored to the original setting
( check AT#GPIO Command )
NOTE: device address, register address where to read from\ write to, and date
bytes have to be written in hexadecimal form without 0x.
Test command reports the supported list of currently available <service>s.
#I2CRD: 00112233445566778899AABBCC
OK
Power Saving Mode Ring - #PSMRI
#PSMRI – Power Saving Mode Ring
<x>
Set command enables/disables the Ring Indicator pin response to an
URC message while modem is in power saving mode. If enabled, a
negative going pulse is generated, when URC message for specific event is
invoked.
The duration of this pulse is determined by the value of <x>.
Parameter:
<x> - RI enabling
0 - disables RI pin response for URC message(factory default)
50-1150 - enables RI pin response for URC messages.
Note: when RING signal from incoming call/SMS/socket listen is enabled, the
behaviour for #PSMRI will be ignored.