Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 199 of 509
Mod. 0808 2011-07 Rev.2
#WAKE - Wake From Alarm Mode
Note: if #WAKE=0 command is issued after an alarm has been set with +CALA
command, but before the alarm has expired, it will answer OK but have no effect.
Read command returns the operating status of the device in the format:
#WAKE: <status>
where:
<status>
0 - normal operating mode
1 - alarm mode or normal operating mode with some alarm activity.
Test command returns OK result code.
Temperature Monitor - #TEMPMON
#TEMPMON - Temperature Monitor
SELINT 2
AT#TEMPMON=
<mod>
[,<urcmode>
[,<action>
[,<hyst_time>
[,<GPIO>]]]]
Set command sets the behaviour of the module internal temperature monitor.
Parameters:
<mod>
0 - sets the command parameters.
1 - triggers the measurement of the module internal temperature, reporting the
result in the format:
#TEMPMEAS: <level>,<value>
where:
<level> - threshold level
-2 - extreme temperature lower bound (see Note)
-1 - operating temperature lower bound (see Note)
0 - normal temperature
1 - operating temperature upper bound (see Note)
2 - extreme temperature upper bound (see Note)
<value> - actual temperature expressed in Celsius degrees.
Setting of the following optional parameters has meaning only if <mod>=0
<urcmode> - URC presentation mode.
0 - it disables the presentation of the temperature monitor URC