Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 466 of 509
Mod. 0808 2011-07 Rev.2
std_twist> and <rev_twist> parameters for the first time: if the read
command is entered, it reports the parameter value just used. If
subsequently the <std_twist> and <rev_twist> are omitted, the read
command reports the parameter value entered the last time.
Read command reports the currently selected value in the format:
# DTMFCFG:
<scaling>,<threshold_1>,<threshold_2>[,<std_twist>[,<rev_twis
t >]]
Test command reports supported range of values for all
parameters.
Digital Voice Interface
Digital Voiceband Interface - #DVI
#DVI - Digital Voiceband Interface
[,<dviport>,
<clockmode>]
Set command enables/disables the Digital Voiceband Interface.
Parameters:
<mode> - enables/disables the DVI.
0 - disable DVI;
1 - enable DVI; audio is forwarded to the DVI block
2 - reserved
<dviport>
2 - DVI port 2 will be used.
<clockmode>
0 - DVI slave
1 - DVI master (factory default)
Read command reports last setting, in the format:
#DVI: <mode>,<dviport>,<clockmode>
Test command reports the range of supported values for parameters
<mode>,<dviport> and <clockmode>
OK
DVI is configured as master providing on DVI Port #2 (the only available)