Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 248 of 509
Mod. 0808 2011-07 Rev.2
Clock management - #CCLK
Set command sets the real-time clock of the ME.
Parameter:
<time> - current time as quoted string in the format:
"yy/MM/dd,hh:mm:ss±zz,d"
yy - year (two last digits are mandatory), range is 00..99
MM - month (two last digits are mandatory), range is 01..12
dd - day (two last digits are mandatory)
The range for dd(day) depends either on the month and on the year it refers
to. Available ranges are:
(01..28)
(01..29)
(01..30)
(01..31)
Trying to enter an out of range value will raise an error
hh - hour (two last digits are mandatory), range is 00..23
mm - minute (two last digits are mandatory), range is 00..59
ss - seconds (two last digits are mandatory), range is 00..59
±zz - time zone (indicates the difference, expressed in quarter of an hour, between
the local time and GMT; two last digits are mandatory), range is -47..+48
d – number of hours added to the local TZ because of Daylight Saving Time
(summertime) adjustment; range is 0-2.
Read command returns the current setting of the real-time clock, in the format
<time>.
Note: if the time is set by the network but the DST information is missing, or the
time is set by +CCLK command, then the <time> format is:
Test command returns the OK result code.
AT#CCLK="02/09/07,22:30:00+04,1"
OK
AT#CCLK?
#CCLK: “02/09/07,22:30:25+04,1”
Clock Mode - #CCLKMODE
Set command enables the local time or the UTC time in AT+CCLK and
AT#CCLK commands and in #NITZ URC