Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 50 of 509
Mod. 0808 2011-07 Rev.2
OK
To call the entry with alphanumeric field “Name”:
ATD>”Name”;
Tone Dial - T
Set command has no effect is included only for backward compatibility with
landline modems.
Pulse Dial - P
Set command has no effect is included only for backward compatibility with
landline modems.
Answer - A
Execution command is used to answer to an incoming call if automatic answer is
disabled.
Note: This command MUST be the last in the command line and must be followed
immediately by a <CR> character.
Data only products do not start the call and command answer is ERROR if a voice
call is requested.
Disconnect - H
Execution command is used to close the current conversation (voice or data).
Note: this command can be issued only in command mode; when a data
conversation is active the device is in on-line mode (commands are not sensed and
characters are sent to the other party), hence escape sequence is required before
issuing this command, otherwise if &D1 option is active, DTR pin has to be tied
Low to return in command mode.