Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 97 of 509
Mod. 0808 2011-07 Rev.2
+CESQ – Extended Signal Quality
1 - -24 dB ≤ Ec/Io < -23.5 dB
2 - -23.5 dB ≤ Ec/Io < -23 dB
...
47 - -1 dB ≤ Ec/Io < -0.5 dB
48 - -0.5 dB ≤ Ec/Io < 0 dB
49 – 0 dB ≤ Ec/Io
255 - not known or not detectable detectable or if the current serving cell is not a
UTRA cell
<rsrq> - reference signal received quality (see 3GPP TS 36.133 subclause 9.1.7).
0 - rsrq < -19.5 dB
1 - -19.5 dB ≤ rsrq < -19 dB
2-19 dB ≤ rsrq < -18.5 dB
...
32 - -4 dB ≤ rsrq < -3.5 dB
33 - -3.5 dB ≤ rsrq < -3 dB
34 - -3 dB ≤ rsrq
255 - not known or not detectable detectable or if the current serving cell is not a
EUTRA cell
<rsrp> - type, reference signal received power (see 3GPP TS 36.133 subclause
9.1.4).
0 - rsrp < -140 dBm
1 - -140 dBm ≤ rsrp < -139 dBm
2 - -139 dBm ≤ rsrp < -138 dBm
...
95 - -46 dBm ≤ rsrp < -45 dBm
96 - -45 dBm ≤ rsrp < -44 dBm
97 - -44 dBm ≤ rsrp
255 not known or not detectable detectable or if the current serving cell is not
Test command returns the supported range of values of the parameters <rxlev>,
<ber>, <rscp>, <ecno>, <rsrq>, <rsrp>.
Indicator Control - +CIND
+CIND - Indicator Control
[<state>
[,<state>[,…]]]
Set command is used to control the registration state of ME indicators, in order to
automatically send the +CIEV
URC, whenever the value of the associated indicator
changes. The supported indicators (<descr>) and their order appear from test
command AT+CIND=?