Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 387 of 509
Mod. 0808 2011-07 Rev.2
4.1.6.8. Enhanced IP Easy Extension AT Commands
Authentication User ID - #USERID
#USERID - Authentication User ID
SELINT 2
AT#USERID=
[<user>]
Set command sets the user identification string to be used during the authentication
step.
Parameter:
<user> - string type, it’s the authentication User Id; the max length for this value is
the output of Test command, AT#USERID=? (factory default is the
empty string “”).
Note: this command is not allowed for sockets associated to a GSM context (see
#SCFG).
AT#USERID?
Read command reports the current user identification string, in the format:
#USERID: <user>
AT#USERID=?
Test command returns the maximum allowed length of the string parameter <user>.
Example
AT#USERID="myName"
OK
AT#USERID?
#USERID: "myName"
OK
Authentication Password - #PASSW
#PASSW - Authentication Password
SELINT 2
AT#PASSW=
[<pwd>]
Set command sets the user password string to be used during the authentication
step.
Parameter:
<pwd> - string type, it’s the authentication password; the max length for this value
is the output of Test command, AT#PASSW=? (factory default is the
empty string “”).
Note: this command is not allowed for sockets associated to a GSM context (see
#SCFG).
AT#PASSW=?
Test command returns the maximum allowed length of the string parameter <pwd>.
Example
AT#PASSW="myPassword"
OK

Table of Contents