Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 36 of 509
Mod. 0808 2011-07 Rev.2
Display Configuration And Profile - &V
&V - Display Current Base Configuration And Profile
Execution command returns some of the base configuration parameters
settings.
Note: the row of information about CTS (C106) OPTIONS is in the output of &V
only for compatibility reasons and represents only a dummy value.
Display Configuration And Profile - &V0
&V0 - Display Current Configuration And Profile
Execution command returns all the configuration parameters settings.
Note: this command is the same as &V
, it is included only for backwards
compatibility.
Note: the row of information about CTS (C106) OPTIONS is in the output of &V0
only for compatibility reasons and represents only a dummy value.
S Registers Display - &V1
&V1 - S Registers Display
Execution command returns the value of the S registers in decimal and hexadecimal
value in the format:
REG DEC HEX
<reg0> <dec> <hex>
<reg1> <dec> <hex>
...
where
<regn> - S register number
000..005
007
012
025
038
<dec> - current value in decimal notation
<hex> - current value in hexadecimal notation