Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 307 of 509
Mod. 0808 2011-07 Rev.2
<storing_mode>:
0 – the counters are saved in NVM at every shuthdown (default)
1 – the counters are saved in NVM at every shuthdown and periodically
at regular intervals specified by <storing_period> parameter
<storing_period> - number of hours after that the counters are saved;
numeric value in hours; range (0,8-24); 0 is default value and means no set
period (as <storing_mode>=0)
Note: the values set by command are directly stored in NVM and don’t
depend on the specific AT instance
Note: when the functionality is disabled with <enable>=0, the data
counters are stopped but not reset: to reset them (except life counters) set
<rule_enable>=0 with AT#CONSUMECFG command.
Note: when the functionality is disabled with <enable>=1, the data
counters are stopped except life counters.
Note: the life counters are never reset, neither in terms of counted data nor
in terms of time
Read command returns the current settings for all parameters in the
format:
#ENACONSUME: <enable>,<storing_mode>,<storing_period>
Test command reports the supported range of values for all parameters
Report consume statistics - #STATSCONSUME
#STATSCONSUME – report consume statistics
nter_type>]
Execution command reports the values of the life counters for every type
of service or the values of period counters for every rule.
Parameter:
<counter_type>
Type of counter: range (0-1)